IDAS 2823 Capacitance and Dissipation Factor Meter (Tangens Delta)

HAEFELY_2823
Catalog ID: 2823

The High-Precision Dielectric-Loss Analyzing System 2823 is designed for measurement of very low dielectric losses and impedances (Dissipation Factor and Power Factor) of high-voltage apparatus (e.g. extruded insulation on power cables). The instrument works on the principle of a combined bridge-vector-meter and is capable of analyzing capacitive and inductive loads – especially shunt reactors – with outstanding accuracy and stability certified by a leading metrology institute. The use of optically decoupled connection allows complete galvanic isolation between control room and test field, and guarantees the personnel the highest safety level.

read more

WA 2293 Winding Analyzer

The 2293 is an automatic winding analyzer, optimized for three phase power and distribution transformermeasurements.It uniquely combines winding resistance measurement, turns ratio measurement, core demagnetization, transformer type detection, magnetic balance and heat run test (temperature rise and cooling curve) in the fastest single instrument solution on the market.
read more

IDAS 2823REF High-Precision Capacitance and Dissipation Factor Meter

HAEFELY_2823REF
Catalog ID: 2823-REF

The High-Precision Dielectric-Loss Analyzing System 2823-REF is designed for measurement of very low dielectric losses and impedances (Dissipation Factor and Power Factor) of high-voltage apparatus (e.g. extruded insulation on power cables). The instrument works on the principle of a combined bridge-vector-meter and it is capable of analyzing capacitive and inductive loads – especially shunt reactors – with outstanding accuracy and stability certified by a leading metrology institute.The use of optically decoupled connection allows complete galvanic isolation between control room and test field, and guarantees the highest safety level to the personnel.

read more

FRA 5310

HAEFELY_FRA_5310
Catalog ID: Frequency Response Analyzers FRA 5310
The FRA 5310 is a diagnosis instrument for the detection of mechanical distortions of transformer winding. These distortions can be caused by electro-dynamical forces which appear during short-circuits or by transportation damages during movement.The Sweep Frequency Response Analysis method is based on winding transfer function measured in a wide range of frequency. The system records the transformers _frequency response fingerprint”. Even small winding movements or distortions will cause legible change of transfer curve, which can be detected. Special active measuring probes minimize the influence of test object connecting and earthing which results in
read more

2914 Solid Test Cell

HAEFELY_2914

Catalog ID: 2914 Solid Test Cell

The 2914 test cell measures dissipation factor, relative permittivity, and specific resistivity of solid insulating materials such as paper and plastic foils.The test cell is equipped with a shielded measuring electrode which eliminates partial capacitances that influence test results.

read more

2903 Oil Test Cell

HAEFELY_2903

Catalog ID: 2903 Oil Test Cell

The precision test cell type 2903 measures the dielectric properties of liquid insulants such as insulating oil, it determines the dissipation factor tan delta and the relative permittivity (dielectric constant) r as well as the specific resistivity.The test cell has been designed as a cylindrical capacitor with a shielded measuring electrode (guard ring capacitor) & thus avoids partial capacitances, which might influence the test results.

read more

5288a Resonating Inductor

HAEFELY_5288a

Catalog ID: 5288a

The capacitive load range of the MIDAS System can be increased by using this Compensator Reactor (resonating inductor).The 5288a provides a manual tunable 12 kV, 40 kVA inductor coil. It comes into use mainly for power generator or other high capacitive loads on on-site testing.

read more

3320 Precision Standard Capacitor

HAEFELY_3320

Catalog ID: 3320 Air Isolated

These standard fixed and variable capacitors are especially for precision measurements of high accuracy. Because of their high insulation resistance, small self-inductance and dissipation factor, these standards may be used within large frequency ranges up to very high frequencies.

read more

4861 High Precision Standard Electronic Voltage Dividers

HAEFELY_ 4860 HAEFELY_ 4860

Catalog ID: 4861

The 4860 series (control unit and capacitive HV divider with compressed gas and air caps) high precision standard voltage divider is used as a variable comparison standard in the differential method (bridge) measurement of high voltage instrument transformers.The special active guard controlled design of this divider set results in highest accuracy. This standard voltage divider is ideal for integration with the 2767 or 2769 test set in a full remote controlled instrument voltage transformer test system.High Voltage Divider Unit The high voltage divider unit comprises a capacitive high voltage divider (compressed gas standard capacitor C1 and air

read more